AG Reederei Norden-Frisia, headquartered on Norderney, is one of the most important ferry and supply companies on the North Sea coast of Lower Saxony. This long-established company was founded in 1871 and today operates year-round passenger, vehicle, and freight services between Norddeich and the islands of Norderney and Juist.
The shipping company has a fleet of about twelve ferry, passenger, and cargo ships and employs approximately 280 people, with annual revenue of about 46 million euros in 2024.
Fire Alarm System for the Ferry Terminal on Norderney
The “Haus Schiffahrt” ferry terminal operated by AG Reederei Norden-Frisia on Norderney opened in 2017 and was built at a cost of approximately 10 million euros. The building, modeled after a sand dune, connects the two ferry piers at the harbor and serves as a central waiting, information, and check-in area for over 2 million passengers annually. During peak season, up to 14 ferries operate daily between Norddeich and Norderney.
In addition to service, lounge, and administrative areas, the terminal features technical operational areas with stringent requirements for preventive fire protection. The fire alarm system (BMA) plays a central safety role in early fire detection, triggering alarms, and quickly notifying the fire department. In addition, the system controls key fire protection equipment such as smoke exhaust systems, door closers, and ventilation systems. The fire alarm system consists of a fire alarm control panel, smoke and heat detectors, manual fire alarm buttons, as well as audible and visual alarms, and is directly connected to the fire department.
Modern Fire Alarm Technology for a High-Traffic Ferry Terminal
The CWS Fire Safety branch in Bremen planned, installed, and successfully commissioned the fire alarm system at the Frisia Terminal. This included full project management, including coordination with the relevant authorities and experts. A Detectomat DC3500 with intelligent Loop3000 ring bus technology was installed. The technology processes all fire and fault signals and controls the alarm and fire protection functions in the fire alarm control panel.
Key features of the fire alarm control panel:
- Color touchscreen display for operation and event display
- Integrated event logging
- Programmable control functions
- EN 54-compliant emergency power supply
- Networking via CON-Xnet
A total of 312 OTI multi-criteria detectors are installed for automatic early fire detection. The detectors simultaneously monitor smoke and temperature levels, thereby enabling reliable fire detection with a reduced false alarm rate. This ensures that waiting and lounge areas, traffic areas, technical and operational rooms, as well as escape and rescue routes, are protected.
In addition, 17 manual fire alarm buttons are installed in escape routes and publicly accessible areas. The fire alarm system is also integrated with other fire protection equipment and complies with the requirements of EN 54 and DIN VDE 0833.
“Since I regularly visit Norderney in my free time, this project held special significance for me personally. At the same time, the Frisia Terminal, with its high foot traffic and open building structure, presents unique challenges for technical fire protection. This made it all the more important to implement a reliable and future-proof fire alarm solution that sustainably supports the protection of passengers and employees as well as the operational safety of the terminal,” said Peter Schindler, project manager at CWS Fire Safety Bremen.
Regular Maintenance and Ensuring Operational Readiness
In addition to planning and installation, the CWS Fire Safety branch in Bremen also handles the regular maintenance and servicing of the fire alarm system at the Frisia Terminal. The system is tested and maintained in accordance with DIN 14675, DIN VDE 0833, and EN 54. This includes quarterly inspections and at least one annual maintenance service performed by certified specialists.
Services include, among other things:
- Functional tests of automatic detectors and manual fire alarm buttons
- Checking the alarm and control functions
- Testing of the emergency power supply
- Inspection of fire department interfaces
- Documentation of all maintenance and event data
Through continuous support, CWS Fire Safety ensures the long-term safe and code-compliant operation of the fire alarm system.
Importance for Safety on Norderney
On islands such as Norderney, fire alarm systems are of particular importance, as additional emergency personnel and specialized support from the mainland are limited and arrive with a delay. Early fire detection is therefore crucial for limiting damage and protecting people in a timely manner. Incident reports from the Norderney Fire Department show (see sources) that automatic fire alarm systems have already prevented major damage on multiple occasions, as fires were detected early and quickly contained. These experiences underscore the critical importance of a fully functional fire alarm system, including in the Frisia reception building.
Partnership on Equal Footing
10 Years of Trust
Johann Pommer, Sales Representative for Norderney at AG Reederei Norden-Frisia
“We have a long-standing and trusting partnership with CWS Fire Safety—from the installation of the fire alarm system to ongoing maintenance and support in day-to-day operations. Especially in a high-traffic terminal like the one here on Norderney, reliability, fast response times, and technical expertise are crucial. This makes it all the more important for us to have a fire safety partner by our side who thoroughly understands the specific requirements of our infrastructure.”
|
Fire Safety Products
|
Fire Safety Services
|